After Engine Start 2 / 2
Continuing
If the ST-BY generator is not connected after 10 seconds (voltage < 27
V is a possible cue):
13 - GENERATOR RESET ST-BY
pushbutton .................. Press
To reset ST-BY generator
14 - AMPS / VOLTS ......................................................... Check
The indicated voltage should be in the green
range
15 - GENERATOR selector ........................................................ MAIN
PFD 1, MFD and PFD 2
NOTE
Detailed control procedures of the avionics system are described in the
Garmin Integrated Flight Deck Pilot's Guide.
16 - Brightness .................................................................................... Adjust
17 - DISPLAY BACKUP
pushbutton ................................................... Check
Then return to NORMAL mode
18 - CAS ...................................................................................................... Check
Check engine parameters
19 - FAN selector ................................................................................. As required
20 - TEMP selector ...................................................................................... Adjust
21 - SEATS HTRS MASTER switch .................................................... As required
22 - BLEED switch ....................................................................................... AUTO
23 - DEFOG pushbutton ...................................................................... As required
NOTE
The demisting function is automatically switched OFF 10 minutes after
the DEFOG pushbutton has been set to ON.
End of procedure.