Airspeed Indicating System Failure 1 / 1
Symptoms: erroneous indication in flight.
1 - PITOT L/R & ST
ALL HTR switch ................................................... Check ON
If symptoms persist:
2 - ALTERNATE STATIC SOURCE selector ....................... Pull thoroughly
3 - Use standby instrument only.
If symptoms persist, as well as on the electronic standby instrument on the
left-side instrument panel:
4 - Perform a precautionary approach maintaining an adequate
airspeed.
End of procedure.