Engine Start 3 / 3
► Continuing
18 - IGNITION ........................................................................... Check OFF
After 30 seconds:
19 - Starter ........................................................... Check
OFF automatically
20 -
STARTER .......................................................................... Check OFF
CAUTION
Do not attempt another engine start after automatic or manual aborted
start, except if the previous start sequence was aborted due to:
- low battery voltage,
- FUEL TANK SELECTOR in the OFF
position, or
- other than engine-related reason.
For all other cases, the airplane is grounded. Inform maintenance
department.
End of procedure ■
When Ng > 45%:
21 - Starter .................................................................... Check OFF
automatically
22 -
STARTER ................................................................................... Check OFF
23 - AUX BP ON ................................................................................ Check OFF
When Ng > 55%:
24 - IGNITION .................................................................................... Check OFF
25 - Engine parameters ............................................................................... Check
NOTE
In ISA conditions at sea level, Ng
≈ 58.5%.
Ng may vary between 55% and 63% depending on external conditions.
End of procedure.
Pilot's Information Manual
Section 4
Normal Procedures
PIM TBM 960 - Edition 0
Rev. 01
Page 4.4.25
PIM - DO NOT USE FOR FLIGHT OPERATIONS