Manual Dry Motoring 2 / 2
Continuing
If ignition symptoms occur (ITT increasing):
14 - STARTER switch
............................................................................ OFF
Dry motoring sequence is stopped.
End of procedure ■
After 30 seconds maximum:
15 - STARTER switch ..................................................................................... OFF
16 -
STARTER ................................................................................... Check OFF
17 - Engine crank mode ................................................................................. OFF
T
o deactivate the engine crank mode, press again the
crank mode button in the dedicated GTC sub-menu
NOTE
It is recommended to avoid more than two consecutive motoring between two
engine starts, to minimize potential leakages of the bearing #1 lab seal.
End of procedure.