Figure 5-51 PTZ
Step 2 Configure the settings for the PTZ connection parameters.
Table 5-22 PTZ connection parameters
Parameter Description
Channel
In the
Channel
list, select the channel that you want to connect the PTZ
camera to.
Type
Local: Connect through RS-485 port or coaxial cable.
Remote: Connect through network by adding IP address of PTZ
camera to the Device.
Control Mode
In the
Control Mode
list, select
SerialPort
or
HDCVI
. For HDCVI series
product, select
HDCVI
. The control signal is sent to the PTZ through the
coaxial cable. For the serial mode, the control signal is sent to the PTZ
through the RS-485 port.
Protocol
In the
Protocol
list, select the protocol for the PTZ camera. For example,
select
HDCVI3.0
.
Address
In the
Address
box, enter the address for PTZ camera. The default is 1.
The entered address must be the same with the address configured on
the PTZ camera; otherwise the PTZ camera cannot be controlled from
the Device.
Baud Rate
In the
Baud Rate
list, select the baud rate for the PTZ camera. The
default is 9600.

Table of Contents

Other manuals for Dahua Technology DH-XVR1B04-I

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dahua Technology DH-XVR1B04-I and is the answer not in the manual?

Dahua Technology DH-XVR1B04-I Specifications

General IconGeneral
BrandDahua Technology
ModelDH-XVR1B04-I
CategoryDVR
LanguageEnglish

Related product manuals