Figure 5-39 PTZ (remote)
Step 2 Congure parameters.
Table 5-12 PTZ parameters
Parameter
Description
Channel Select the channel that you want to connect the PTZ camera to.
Type
●
Local: Connect through RS-485 port.
●
Remote: Connect through network by adding IP address of PTZ camera
to the Device.
Protocol Select the protocol for the PTZ camera such as PELCOD.
Address
Enter the address for PTZ camera. The default is 1.
The entered address must be the same with the address congured on the
PTZ camera; otherwise the system cannot control PTZ camera.
Baud rate Select the baud rate for the PTZ camera. The default is 9600.
Data Bit The default value is 8.
Stop Bit The default value is 1.
Parity The default value is None.
Step 3 Click Apply.
5.6.7.2 PTZ Control
You can use the PTZ control panel to perform the operations such as directing camera in eight
directions, adjusting zoom, focus and iris settings, and quick positioning.
User's Manual
159