Parameter Designation Setting
0-01 Language
1-20 Motor Power [kW]
1-22 Motor Voltage [V]
1-23 Motor Frequency [Hz]
1-24 Motor Current [A]
1-25 Motor Nominal Speed [rpm]
5-12 Terminal 27 Digital Input [0] No function*
1-29 Automatic Motor Adaptation (AMA) [1] Enable complete AMA
3-02 Min Reference [rpm]
3-03 Max Reference [rpm]
3-41 Ramp 1 Ramp-up Time [sec]
3-42 Ramp 1 Ramp-down Time [sec]
3-13 Reference Site
* If terminal 27 is set to “no function”, no connection to +24 V on terminal 27 is necessary.
Select
Changes made
to get information
about:
•
the last 10 changes. Use the [▴] [▾]
navigation keys to scroll between the
last 10 changed parameters.
• the changes made since default set-
ting.
Select
Loggings
to get information about the
display line read-outs. The information is
shown as graphs.
Only display parameters selected in par. 0-20
and par. 0-24 can be viewed. It is possible to
store up to 120 samples in the memory for
later reference.
2. How to Programme FC 300 Programming Guide
18
MG.33.M2.02 - VLT
®
is a registered Danfoss trademark
2