Figure 4-127 Soft Start AC/DC Harness Connections - TTS/TGS/TTH/TGH (Except TTS300/TGS230)
4.17.2 Soft Start AC/DC Harness Removal and Installation
NOTE
ForTTS300/TGS230Compressors,itmaybehelpfultoremovetheSoftStartand/ortheOpen-FrameDC-DCtogainbetteraccessforthis
procedure.
4.17.2.1 Soft Start AC/DC Harness Removal - TTS300/TGS230
1. IsolatecompressorpowerasdescribedinSection1.8ElectricalIsolationonpage22.
2. Disconnectthethree(3)ringterminalslabeledL1,L2,andL3fromtheACBusBars.RefertoFigure4-
128InputRingTerminalRemoval-TTS300/TGS230onpage134.