FC 300, P1K5T4
Cable
length [m]
Mains
voltage
[V]
Rise time
[μsec]
Upeak
[kV]
du/dt
[kV/μsec]
5 480 0.640 0.690 0.862
50 480 0.470 0.985 0.985
150 480 0.760 1.045 0.947
FC 300, P4K0T4
Cable
length [m]
Mains
voltage
[V]
Rise time
[μsec]
Upeak
[kV]
du/dt
[kV/μsec]
5 480 0.172 0.890 4.156
50 480 0.310 2.564
150 480 0.370 1.190 1.770
FC 300, P7K5T4
Cable
length [m]
Mains
voltage
[V]
Rise time
[μsec]
Upeak
[kV]
du/dt
[kV/μsec]
5 480 0.04755 0.739 8.035
50 480 0.207 4.548
150 480 0.6742 1.030 2.828
FC 300, P11KT4
Cable
length [m]
Mains
voltage
[V]
Rise time
[μsec]
Upeak
[kV]
du/dt
[kV/μsec]
36 480 0.396 1.210 2.444
100 480 0.844 1.230 1.165
150 480 0.696 1.160 1.333
FC 300, P15KT4
Cable
length [m]
Mains
voltage
[V]
Rise time
[μsec]
Upeak
[kV]
du/dt
[kV/μsec]
36 480 0.396 1.210 2.444
100 480 0.844 1.230 1.165
150 480 0.696 1.160 1.333
FC 300, P18KT4
Cable
length [m]
Mains
voltage
[V]
Rise time
[μsec]
Upeak
[kV]
du/dt
[kV/μsec]
36 480 0.312 2.846
100 480 0.556 1.250 1.798
150 480 0.608 1.230 1.618
FC 300, P22KT4
Cable
length [m]
Mains
voltage
[V]
Rise time
[μsec]
Upeak
[kV]
du/dt
[kV/μsec]
15 480 0.288 3.083
100 480 0.492 1.230 2.000
150 480 0.468 1.190 2.034
FC 300, P30KT4
Cable
length [m]
Mains
voltage
Rise time
[μsec]
Upeak
[kV]
du/dt
[kV/μsec]
5 480 0.368 1.270 2.853
50 480 0.536 1.260 1.978
100 480 0.680 1.240 1.426
150 480 0.712 1.200 1.334
FC 300, P37KT4
Cable
length [m]
Mains
voltage
[V]
Rise time
[μsec]
Upeak
[kV]
du/dt
[kV/μsec]
5 480 0.368 1.270 2.853
50 480 0.536 1.260 1.978
100 480 0.680 1.240 1.426
150 480 0.712 1.200 1.334
FC 300, P45KT4
Cable
length [m]
Mains
voltage
[V]
Rise time
[μsec]
Upeak
[kV]
du/dt
[kV/μsec]
15 480 0.256 1.230 3.847
50 480 0.328 1.200 2.957
100 480 0.456 1.200 2.127
150 480 0.960 1.150 1.052
FC 300, P55KT5
Cable
length [m]
Mains
voltage
[V]
Rise time
[μsec]
Upeak
[kV]
du/dt
[kV/μsec]
5 480 0.371 1.170 2.523
FC 300, P75KT5
Cable
length [m]
Mains
voltage
[V]
Rise time
[μsec]
Upeak
[kV]
du/dt
[kV/μsec]
5 480 0.371 1.170 2.523
FC 300 Selection FC 300 Design Guide
92 MG.33.BD.02 - VLT
®
is a registered Danfoss trademark
44

Table of Contents

Other manuals for Danfoss VLT FC 100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT FC 100 and is the answer not in the manual?

Danfoss VLT FC 100 Specifications

General IconGeneral
BrandDanfoss
ModelVLT FC 100
CategoryDC Drives
LanguageEnglish

Related product manuals