Symbologies
114
Magellan
TM
3300HSi
Code 39 Length 1, Length 2 Programming Instructions
1. Scan the START/END bar code.
2. Scan either the Set Length 1 or Set Length 2 bar code.
3. Turn to
Appendix C, Alpha-Numeric Pad and scan the two digits (zero padded) representing
the length in decimal notation.
4. Scan the START/END bar code.
NOTE
For Code 39 bar codes, all check, data and full ASCII
shift characters are included in the length calculations.
Start/Stop characters are not included.
START / END
PROGRAMMING bar codes
DEFAULT SETTING FOR THIS FEATURE: 02
Set Length 1
Set Length 2
DEFAULT SETTING FOR THIS FEATURE: 50

Table of Contents

Other manuals for Datalogic Magellan 3300HSi

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic Magellan 3300HSi and is the answer not in the manual?

Datalogic Magellan 3300HSi Specifications

General IconGeneral
Scanner type1D
Decoding standardsGS1, MicroPDF417, PDF417
Optical sensor resolution1280 pixels
Light levels (direct sunlight)0 - 86100 lx
Dimensions (WxDxH)152 x 87 x 152 mm
Power consumption (active)9.9 W
Standard interfacesUSB, RS-232
Input voltage90 - 264 V
Power requirements47 - 63 Hz
Power consumption (standby)2 W
CertificationRoHS, EN 60825-1, IEC 60825, IEC 60825-1
Product colorStainless steel
Storage temperature (T-T)-40 - 70 °C
Operating temperature (T-T)0 - 40 °C
Operating relative humidity (H-H)5 - 95 %
Harmonized System (HS) code84716070
Weight and Dimensions IconWeight and Dimensions
Weight790 g