EasyManua.ls Logo

Datalogic Magellan 3300HSi

Datalogic Magellan 3300HSi
216 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2
Magellan
TM
3300HSi
Datalogic Handheld Data Format Requirements
The following sections describe label transmission formats that are typically observed in factory configurations of
Datalogic handheld scanners.
RSS-14
Prefix must be ASCII characters ‘R4’
Check character must be included in label
Application identifier “01” must follow the prefix and preceed the base label
Label length excluding prefix characters must be 16 characters.
Example: ‘R40101044123456789’
RSS Expanded
Prefix must be ASCII characters ‘R4’
Check character must be included in label
UPC-A
Number system must be included in label data.
Check digit must be included in label data and is assumed to be correct.
Prefix must be an ASCII character 'A' - total length including prefix must be 13.
Example: 'A060992011187'.
UPC-A with 2-Digit Supplemental
Number system must be included in label data.
Check digit must be included in label data and is assumed to be correct.
Supplemental data is appended to base label.
Prefix must be an ASCII character 'A' - total length including prefix must be 15.
Example: 'A06099201118712'.
UPC-A with 5-Digit Supplemental
Number system must be included in label data
Check digit must be included in label data and is assumed to be correct
Prefix must be an ASCII character 'A' - total length including prefix must be 18
Example: 'A06099201118712345'
UPC-A with Code 128 Supplemental
Number system must be included in label data.
Check digit must be included in label data and is assumed to be correct.
Supplemental data is appended to base label.

Table of Contents

Other manuals for Datalogic Magellan 3300HSi

Related product manuals