General Features
24
Magellan
TM
3300HSi
External Read Indicator (ERI) Active State High
ERI Timeout
Specifies the amount of time the External Read Indicator (ERI) signal is held active for a good
read.
NOTE
This feature is available only through use of a
special cable.
START / END
PROGRAMMING bar codes
ERI Active State = High
ERI Active State = Low
DEFAULT
START / END
PROGRAMMING bar codes
Sets the ERI timeout duration using hex values from 000 to 255 in increments of ten milliseconds (10ms or 0.01 seconds). To config-
ure this feature, scan the “START/END” bar code above to place the unit in Programming Mode, then the “Set ERI Timeout, followed
by the two digits (zero padded) from the Alphanumeric table in
Appendix C, Alpha-Numeric Pad representing the desired time
value. Exit programming mode by scanning the “START/END” bar code again.
DEFAULT SETTING FOR THIS FEATURE: 20 milliseconds (02)
Set ERI Timeout