6-56 Magellan
®
9500
EAS Deactivation Duration — Coupled
Specifies the amount of time EAS deactivation is operative once the func-
tion has been initiated following a bar code read.
To set the EAS Deactivation Duration — Coupled:
1. Scan the SWITCH bar code.
2. Scan the bar code, SET EAS DEACTIVATION DURATION —
COUPLED below. You’ll need to cover any unused bar codes on
this and the facing page to ensure that the scanner reads only the bar
code you intend to scan.
3. Scan the appropriate digits from the keypad in Appendix C that rep-
resent the desired duration. The selectable range is 1-255, which is
the duration in 10-millisecond increments. Pad all single and double
digit numbers with leading zeroes to yield a three-digit entry (001-
255).
Examples:
005 = 50ms
040 = 400ms
250 = 2,500ms (2.5 seconds)
4. The scanner will automatically exit Programming Mode when the
appropriate amount of digits have been scanned.
SET EAS DEACTIVATION DURATION — COUPLED
NOTE
This setting pertains only to units configured for EAS Coupled Mode. Refer-
ence the EAS Mode description for more information about Coupled and
Decoupled EAS operation.