RSS Expanded Enable
Product Reference Guide 6-187
RSS Expanded Maximum Label Length
This feature specifies the maximum allowable length of an RSS Expanded
label.
To set this feature:
1. Scan the SWITCH bar code.
2. Scan the bar code,
SET RSS EXPANDED MAXIMUM LABEL
LENGTH
below. You’ll need to cover any unused bar codes on this
and the facing page to ensure that the scanner reads only the bar
code you intend to scan.
3. Scan the appropriate digits from the keypad in Appendix C that rep-
resent the desired maximum label length. The selectable range for
this option is 00 to 74. Pad all single digit numbers with a leading
zero to yield a two-digit entry (00-74).
4. Complete the programming sequence by scanning the SWITCH
bar code.
SET RSS EXPANDED MAXIMUM LABEL LENGTH
NOTE
Length in this case includes check and data characters. This applies when
RSS Expanded Length Control is set to variable-length decoding.
Maximum Label Length should be greater than or equal to Minimum Label
Length.