Product Reference Guide F-7
Code 39
Check character must be included in label data.
Label length including start, stop and check characters and exclud-
ing prefix character must meet requirements imposed by the main
scanner's fixed or variable label length control for this symbology
type.
Start and stop characters "*" must be included in label.
Prefix must be an ASCII character '*'.
Example : '**Code 39.TEST*'.
Code 39-Pharmacode
Check character must be included in label data.
Label length including start, stop and check characters and exclud-
ing prefix character must meet requirements imposed by the main
scanner's fixed or variable label length control for this symbology
type.
Start and stop characters "*" must be included in label.
Prefix must be an ASCII character 'p'.
Example: 'p*123456789*'.
I 2 of 5
Check character must be included in label data.
Label length including check characters and excluding prefix charac-
ter must meet requirements imposed by the main scanner's fixed or
variable label length control for this symbology type.
Prefix must be an ASCII character 'i'.
Example: 'i0123456789'.