Product Reference Guide F-15
Code 128 / EAN128
Prefix must be either ASCII characters ']C0', ']C1' or ']C2'.
Label length excluding prefix character must meet requirements
imposed by the main scanner's fixed or variable label length control
for this symbology type.
If EAN-128 Symbology is Enabled
and prefix is ']C1', label will be
identified as an EAN128 otherwise it is identified as a Code 128.
A prefix of ']C0' designates that no function code is present in the
1st or 2nd character position.
A prefix of ']C2' designates that a function code 1 is present in the
2nd character.
Example : ']C0Code_128.Test'.
PDF417
Prefix must be an ASCII characters ']L0'.
Label length excluding prefix character cannot exceed 300 charac-
ters. In addition to this, label length excluding prefix character must
meet requirements imposed by the main scanners fixed or variable
label length control for this symbology type.
Example : ']L0pdf_test_label'.