EasyManua.ls Logo

Datalogic PowerScan 7000 2D - Page 165

Datalogic PowerScan 7000 2D
205 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Serial Programming Commands
10-10 PowerScan
®
7000 2D
LED - Good Read
Off BEPLED0
3-3
*On BEPLED1 3-3
Number of Beeps -
Good Read
*1 BEPRPT
3-3
Range 1 - 9 BEPRPT# 3-3
Reread Delay
Short (500 ms) DLYRRD500
3-4
*Medium (750 ms) DLYRR750 3-9
Long (1000 ms) DLYRRD1000 3-9
Extra Long (2000 ms) DLYRRD2000 3-9
User-Specified
Reread Delay
Range 0 - 30,000 ms DLYRRD##### 3-9
Good Read Delay
*No Delay DLYGRD0
3-4
Short Delay (500 ms) DLYGRD500 3-4
Medium Delay (1000 ms) DLYGRD1000 3-4
Long Delay (1500 ms) DLYGRD1500 3-4
User-Specified
Good Read Delay
Range 0 - 30,000 ms DLYGRD##### 3-4
Trigger Mode
*Manual/Serial Trigger TRGMOD0
3-5
Read Time-Out
(0 - 300,000 ms) *0
TRGSTO####
3-5
Manual Trigger, Low Power TRGMOD2 3-5
Low Power Time-Out Timer
( 0 - 300 seconds) *120
TRGLPT###
3-6
Scan Stand
Scan Stand Mode TRGMOD4
3-7
Scan Stand Symbol FNC3 3-7
Presentation Presentation Mode TRGMOD3 3-7
Presentation LED
Timer
LEDs Off TRGPCK0
3-8
*LEDs On TRGPCK1 3-8
Presentation Sen-
sitivity
Range 0-20 (*1) TRGPMS## 3-8
Hands Free Time-
Out
Range 0 - 300,000 ms
TRGPTO#####
#
3-9
Selection
Setting
* Indicates default
Serial
Command
# Indicates a
numeric entry
Page

Table of Contents

Other manuals for Datalogic PowerScan 7000 2D

Related product manuals