Enter Configuration
Exit and Save Configuration
Ì$+;Î
16-KEY DK MODEL PARAMETERS
Ì$-?Î
154
OPERATIVE MODE
MODE SELECTION
This feature allows the PowerScan PM8300-DK to operate in one of two basic operative modes:
SDIM (Simple Data Input Mode)data entered, either on the keypad or read via
barcode, is transmitted the host once the enter key is pressed, following the
formatting rules described in the previous paragraph.
QTY/CODE (Quantity/Code Mode)Refer to the next section, QTY/CODE MODE
PARAMETERS.
Simple Data Input
Mode
Quantity/Code Mode
ENTER KEY CONFIGURATION
This command is active only when the scanner is in Simple Data Input Mode. It defines the
behavior of the enter key when no data has been previously entered. By default an error sound
is generated; it can also be configured to transmit a "null" character.
Generate error sound
send null char
Bg2

Table of Contents

Other manuals for Datalogic PowerScan M8300

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic PowerScan M8300 and is the answer not in the manual?

Datalogic PowerScan M8300 Specifications

General IconGeneral
Scanner type1D
Maximum range30 m
Read rate (max)40 reads/s
Yaw reading angle-60 - 60 °
Decoding standardsGS1 DataBar, Code 16K, Code 49, GS1 DataBar Expanded Stacked, GS1 DataBar Stacked, GS1 DataBar Stacked Omnidirectional
Tilt reading angle-20 - 20 °
Pitch reading angle-55 - 55 °
Operating time240 min
Dimensions (WxDxH)114 x 69 x 210 mm
BluetoothNo
Operating frequency910 MHz
Input voltage10 - 30 V
Battery capacity2150 mAh
Power requirements0.33 - 1A
Number of reads per charge60000
CertificationIP64, China RoHS, EU RoHS, CDRH Class II, IEC 60825-1 Class 2
Keys quantity3 keys
Product colorBlack, Yellow
LED indicatorsCharging, Power
Display resolution32 x 96 pixels
Storage temperature (T-T)-20 - 70 °C
Operating temperature (T-T)-20 - 50 °C
Operating relative humidity (H-H)0 - 90 %
Weight and Dimensions IconWeight and Dimensions
Weight393 g