define function key
Enter Configuration Exit and Save Configuration
56
PowerScan™ PD9330/PBT9300/PM9300
1. Read the above code to associate a Function Key or the Shift key (if
defined as F5).
2. Specify which Function Key you want to associate (F1 – F4 or Shift F5)
by scanning a barcode (1-5) from the hex numeric table in the back of
this manual.
3. Select the label command you want to assoc
iate from the table on page
55. Scan a barcode from the hex numeric table corresponding to the
command ID (0-A).
STRING TABLE
The Powerscan™ 16-key model allows you to define a String Table, a data-
base with room for five entries, from
String1 to String5, which can be
recalled using a Function Key. This is done with Function Key Programming,
described on page 55.
The string can be a single ‘char’. Default = empty strings.
define string
1. Read the above code.
2. Select the string number you want to add by scanning a barcode (1 – 5)
from the hex numeric table in the back of this manual.
3. Select the desired string length by s
canning a barcode (0 – A) from the
hex numeric table.
4. Define the label string by scanning characters or numerals from the
h
ex numeric table.

Table of Contents

Other manuals for Datalogic PowerScan PM8300

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic PowerScan PM8300 and is the answer not in the manual?

Datalogic PowerScan PM8300 Specifications

General IconGeneral
BrandDatalogic
ModelPowerScan PM8300
CategoryBarcode Reader
LanguageEnglish

Related product manuals