Network Parameters
Product Reference Guide
79
Master Header/Terminator Selection
In addition to the standard header/terminator selection, the Master cradle
can add its own header/terminator to the entire message sent to the Host.
In the STAR-System™ network headers and terminators for all RF Devices are
disabled by default.
The Master header and terminator default values are as follows depending
on the interface selection towards the Host:
RS-232: no header, terminator CR-LF
WEDGE: no header, terminator ENTER
Address Stamping
It is possible to include the reader address in the message sent to the host.
The Reader Address Stamping and the Cradle Address Stamping parameters
consist of a 4-digit number in the range 0000 to 1999.
For message output format, refer to MESSAGE FORMATTING on page 81.
Address Delimiter
The Address Delimiter allows a character to be included to separate the
reader Address stamping field from the next field in the message. Any char
-
acter can be included in the hexadecimal range from 00 to FE.
For message output format, refer to MESSAGE FORMATTING on page 81.