EasyManuals Logo

Datalogic VS Series User Manual

Datalogic VS Series
55 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #35 background imageLoading...
Page #35 background image
ADVANCED FUNCTIONS
29
8
Another confirmation will be requested. To proceed press ARROW UP otherwise, press
ARROW DOWN to abandon. In both cases, the information label will display the operation
result and a refresh of the panel names will be made.
8.3.8 Cancellation of all the DataVS2 Slots
To cancel all the DataVS2 memory slots no specific slot has to be selected but the user must
only move the focus on the “Delete ALL” icon on the bottom right side of the screen and
press SET.
Another confirmation will be requested. To proceed press ARROW UP otherwise, press
ARROW DOWN to abandon. In both cases, the information label will display the operation
result and a refresh of the panel names will be made.
NOTA
With this command all the inspections, with the exception of the actual
running one, will be deleted..
8.4 FACTORY RESET
This panel can be accessed only when no DataVS2 are connected and when the factory
reset of the VSM has to be restored.
All the memory slots are going to be cancelled, the network parameters changed and
passwords cancelled.