Dell EMC PowerEdge R540 - Removing the Right Control Panel

Dell EMC PowerEdge R540
177 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Figure 115. Installing left control panel
Next steps
1 Install the air shroud.
2 Install the internal PERC riser.
3 Follow the procedure listed in After working inside your system.
Removing the right control panel
Prerequisites
1 Follow the safety guidelines listed in Safety instructions.
2 Follow the procedure listed in Before working inside your system.
NOTE
: Ensure that you note the routing of the cables as you remove them from the system board. You must route the
cables properly when you replace them to prevent the cables from being pinched or crimped.
3 Remove the internal PERC riser.
Steps
1 Pull the cable latch and disconnect the control panel cable from the system board connector.
2 Using Phillips #1 screwdriver, remove the screws that secure the right control panel assembly to the system.
Installing and removing system components
161