Managing a Switch Stack 159
At this point, if Unit 2 is powered off or rebooted due to an unexpected 
failure, show switch gives the following output:
console#show switch
When the failed unit resumes normal operation, the previous configuration 
that exists for that unit is reapplied by the Master unit.
To permanently remove the unit from the stack, enter into Stack Config 
Mode and use the member command, as the following example shows. 
console#configure
console(config)#stack
console(config-stack)#no member 2
console(config-stack)#exit
console(config)#exit
console#show switch
SW Management
Status
Standby
Status
Preconfig
Model ID
Plugged-
in Model 
ID
Switch
Status
Code
Version
--- --------- ------- -------- ------------------- --------
1 Stack Member PCT7048 PCT7048 OK 9.19.0.2
2 Unassigned PCT7048 Not Present 0.0.0.0
3 Mgmt Switch PCT7048 PCT7048 OK 9.19.0.2
4 Stack Member PCT7048 PCT7048 OK 9.19.0.2
SW Management
Status
Standby
Status
Preconfig
Model ID
Plugged-
in Model 
ID
Switch
Status
Code
Version
--- --------- ------- -------- ------------------- --------
1 Stack Member PCT7048 PCT7048 OK 9.19.0.2
3 Mgmt Switch PCT7048 PCT7048 OK 9.19.0.2
4 Stack Member PCT7048 PCT7048 OK 9.19.0.2