Configuring SNMP 315
You can configure various features on the switch to generate SNMP traps that 
inform the NMS about events or problems that occur on the switch. Traps 
generated by the switch can also be viewed locally by using the Web-based 
interface or CLI.
Why Is SNMP Needed?
Some network administrators prefer to use SNMP as the switch management 
interface. Settings that you view and configure by using the Web-based Dell 
OpenManage Switch Administrator and the CLI are also available by using 
SNMP.
If you do not use NMS software to manage or monitor other devices on your 
network, it might not be necessary to configure SNMP on the switch.
Default SNMP Values
By default, SNMPv2 is automatically enabled on the device. SNMPv1 and 
SNMPv3 are disabled. To enable SNMPv3, you must define a local engine ID 
for the device. The local engineID is by default set to the switch MAC 
address, however when the switch operates in a stacking mode, it is important 
to manually configure the local engineID for the stack. This local engineID 
must be defined so that it is unique within the network. It is important to do 
this because the default engineID in a stack is the MAC address of the master 
unit, which may change if the master unit fails and another unit takes over 
the stack.
Table 12-1 summarizes the default values for SNMP.
Table 12-1. SNMP Defaults
Parameter Default Value
SNMPv1 Disabled
SNMPv2 Enabled
SNMPv3 Disabled
SNMP traps Enabled
SNMP trap receiver None configured
Switch traps Enabled