Supported Select Network Adapter Options and Features
Features Broadcom 5730
Base-T
Intel 1350 Base-T Broadcom 57800
SFP+
Broadcom 57800
Base-T
Intel X540 Base-
T
Link Speed 10/100/1000 Mbps 10/100/1000 Mbps 100 Mbps/1G/10G 100 Mbps/1G/10G 100 Mbps/1G/10G
Link Type 1000BASE-T 1000BASE-T 10GBASE-T, SFP+
DCA/SR
10GBASE-T, SFP+
DCA/SR
10GBASE-T, SFP+
DCA/SR
TCP Chimney
(TOE)
Not Supported Not Supported Supported Supported Supported
iSCSI Offload Not Supported Not Supported Supported Supported Supported
FCoE Offload Not Supported Not Supported Supported Supported Supported
NetQueue/VMQ
IOV
Not Supported Not Supported Supported Supported Supported
SR-IOV Not Supported Not Supported Supported Supported Supported
NIC Partitioning
(NPAR)
Not Supported Not Supported Supported Supported Supported
VNTag/VEB Not Supported Not Supported Supported Supported Supported
Energy Efficient
Ethernet
Not Supported Not Supported Not Supported Not Supported Not Supported
Stateless Offloads
(RSS, CSO, LSO,
LRO)
Supported Supported Supported Supported Supported
NC-SI Passthru
and SEM
Supported Supported Supported Supported Supported
NOTE:
● These cards have two chipsets that offer the choice of either 10 GbE or 1 GbE.
● Only 10 Gb ports have iSCSI HBA support.
● Only 10 Gb ports have FCoE support.
● Only 10 GbEports have switch independent partitioning support. The maximum number of partitions supported is four
(two partitions per 10 Gb port). 1 Gb ports do not support switch-independent partitioning.
● Only 10 GbEports have DCB support.
● Only 10 GbEports have ISCSI TLV support.
System Management Integration
With the R630, the job of deploying, updating, monitoring, and maintaining the Select Network Adapters is fast and easy.
System management integration features include the following:
● Pre-boot: Use the Dell Lifecycle Controller graphical user interface (GUI) to set configuration such as bandwidth allocation
or firmware revision level
● Post-boot: Agent-free out-of-band or high-speed in-band connection over LOM through the Operating System or BMC
pass-thru feature for sensory information
● Automation of firmware and driver version deployment upon component replacement
● Automatic monitoring of NIC status and notification on SNMP traps
● Local- or remote reconfiguration of any NIC: physical or virtual
● PXE boot enabled on all LOM and NDCs for ease of use
● Boot from SAN (iSCSI,or FCoE) configuration for networking devices through the Lifecycle Controller GUI
172