EasyManua.ls Logo

Dell PowerEdge XE8640 - Thermal Air Restrictions; Thermal Restriction Matrix

Dell PowerEdge XE8640
168 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Table 21. Maximum shock pulse specifications
Maximum shock pulse Specifications
Operating Six consecutively executed shock pulses in the positive and negative x, y,
and z axis of 6 G for up to 11 ms.
Storage Six consecutively executed shock pulses in the positive and negative x, y,
and z axis (one pulse on each side of the system) of 71 G for up to 2 ms.
Thermal air restrictions
ASHRAE A3/A4 environment is not supported.
Required to constrain the GPU fan service time to maximum 3 minutes once the environment temp is up to 32°C.
LAAC Pump failure or absence:
Any one of pump failure or absence: PDB CPLD record the status for iDRAC to log the failure and drive all fans to full
speed.
Any two of pump failure: PDB CPLD record the status for iDRAC to log the failure and trigger pFAULT to shutdown the
system for system protection.
Any two of pump absence during the initial system power on process: iDRAC will check the pump presence status from
PDB CPLD MM to gate the power on process and log the message.
LAAC Leak detected: Once the coolant leak is detected, CPLD will proceed the pFAULT process to get system shutdown.
LAAC Coolant loss by evaporation: there's no indicator to detect the percentage of coolant loss
The failure symptom would be GPU throttling / overheat or pump RPM warning.
HDD blank is required if the slot doesn't install HDD.
DIMM blank is not require to be install if total memory populated is more or equal to16.
Do not support net system airflow display in iDRAC WebGUI
BCME 100G_2P FH card (FPM6F) require 85C active optics transceiver / 4WGYD. (NOT support MFS1S00-H003E cable.)
MLNX 100G_2P FH card (8P2T2) require 85C active optics transceiver / 4WGYD. (NOT support MFS1S00-H003E cable.)
Broadcom 25GbE_4P OCP 3.0 card (3Y64D) require 85C active optics transceiver / M14MK. (NOT support 0YR96 cable.)
Thermal restriction matrix
Table 22. Thermal restriction matrix
XE8640
Front configuration 8x 2.5" U.2 / NVMe
Additional attributes 4 x Nvidia H100 700W
Rear configuration 4xFH
Fan type HPR Gold fan
Heatsink type Standard heatsink for CPU
and LAAC for GPU
CPU TDP Processor TDP Die Core count 35°C
5418Y 185W MCC 24 35°C
6448Y/6442Y 225W MCC 32/24 35°C
8462Y+ 300W MCC 32 35°C
8460Y+ 300W XCC 40 35°C
8452Y 300W XCC 36 35°C
8480+/8470/8468 350W XCC 56/52/48 35°C
Technical specifications 27

Table of Contents

Related product manuals