Chapter 2 Devices
2-91
13. The flags related to the Ethernet
SM1001~SM1003, SM1089, SM1090, SM1091, and SM1106~SM1109
SM
number
Description Function
SM1001
Connection status of Ethernet
Port 1
OFFEthernet Port 1 is not connected.
ONEthernet Port 1 is connected.
SM1002
Connection status of Ethernet
Port 2
OFFEthernet Port 2 is not connected.
ONEthernet Port 2 is connected.
SM1003
Connection status of
synchronization fiber cable
OFFSynchronization fiber cable is not
connected.
ON
Synchronization fiber cable is
connected.
SM1089
Maximum MODBUS TCP
connetion number has been
reached.
ONMaximum MODBUS TCP connetion
number has been reached.
SM1090
The TCP connection is busy.
ON: TCP connection timeout
SM1091
The UDP connection is busy.
ON: UDP connection timeout
SM1106 Ethernet connection error
OFF: The Ethernet auto-negotiation
succeeds.
ON: The Ethernet auto-negotiation fails.
SM1107 Basic setting error
OFF: The basic setting is correct.
ON: The basic setting is incorrect.
SM1108 Filter setting error
OFF: The filter setting is correct.
ON: The filter setting is incorrect.
SM1109
Basic management of the
TCP/UDP socket─The local port
is already used.
The flag is ON when the same port is used.
Please refer to section 12.2 in AH500 Operation Manual for more information about the LED
indicators and the error codes.
14. The setting of the email sending
SM1112~SM1113, and SM1116~SM1195
Before sending the email, users have to set the related parameters in the email. If the
setting fails, SM1112 will be set to ON. Besides, SM1113 will be set to ON if the sending of
the email fails.
The triggers (trigger1~trigger8) and the flags (SM1116~SM1195) are described below.
Item
Function
Trigger
1
Trigger
2
Trigger
3
Trigger
4
Trigger
5
Trigger
6
Trigger
7
Trigger
8
Email
trigger
switch
SM1116
SM1126
SM1136
SM1146
SM1156
SM1166
SM1176
SM1186
When the basic setting is incorrect, the flag is set to ON.
Email
trigger
SM1117
SM1127
SM1137
SM1147
SM1157
SM1167
SM1177
SM1187
When the filter setting is incorrect, the flag is set to ON.
Email
trigger
status 0
SM1118
SM1128
SM1138
SM1148
SM1158
SM1168
SM1178
SM1188
When the trigger is enabled and no mail has been sent, the flag is ON.
Email
trigger
status 1
SM1119
SM1129
SM1139
SM1149
SM1159
SM1169
SM1179
SM1189
When the trigger is enabled and the last mail has been sent successfully, the flag is
ON.
Email
trigger
status 2
SM1120
SM1130
SM1140
SM1150
SM1160
SM1170
SM1180
SM1190
When the trigger is enabled and the last mail has been sent in error, the flag is ON.