AH500 Programming Manual
6-76
binary value, and the conversion result is stored in D100. Subsequently, the binary value
in D100 is converted into the binary-coded decimal value, and the conversion result is
stored in Y0.0~Y0.15.
4 2
8 1
10
1
10
0
6 6
10
3
10
2
8 1
8 18 1
X0.15 X0.0
Y0.15 Y0.0
Four-digit binary-coded decimal value
The instruction BIN is used to store
the binary value in D100.
The instruction BCD is used to convert
the value in D100 into the four-digit
binary-coded decimal value.
Four-digit binary-coded decimal type
of seven-segment display
Four-digit binary-coded
decimal type of DIP switch