Chapter 6 Applied Instructions
6-169
X0.0
M10
M12
M11
M13
M14
15
10
15 15
30
30
40
25
111
0 0 0
2
3
4
C10
C11
Current value
SM688
Current value
Additional remark:
1. If S
2
+1 exceeds the device range, the instruction is not executed, SM0 is ON, and the error
code in SR0 is 16#2003.
2. If S
1
+n-1 exceeds the device range, the instruction is not executed, SM0 is ON, and the error
code in SR0 is 16#2003.
3. If D+n-1 exceeds the device range, the instruction is not executed, SM0 is ON, and the error
code in SR0 is 16#2003.
4. If n is less than 1, or if n is larger than 256, the instruction is not executed, SM0 is ON, and the
error code in SR0 is 16#200B.
5. If users declare the operand S
2
in ISPSoft, the data type will be ARRAY [2] of WORD/INT.