EasyManua.ls Logo

Delta AH500 - Page 48

Delta AH500
749 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 2 Devices
2-29
SM Function
CPU5X0-RS2
CPU5X0-EN
CPU5X1-RS2
CPU5X1-EN
CPU560-EN2
OFF
ON
STOP
RUN
RUN
STOP
Attribute
Default
*SM1155
When trigger 4 is triggered and the attachment
is not found, SM1155 is ON.
×
×
OFF
R OFF
*SM1156
It is the switch of trigger 5 in the email.
×
×
OFF
R
OFF
*SM1157
Trigger 5 in the email
×
×
OFF
R
OFF
*SM1158
When trigger 5 is triggered but the email cannot
be sent due to the Ethernet connection failure;
SM1158 is ON.
×
×
OFF
R OFF
*SM1159
When trigger 5 is triggered and the email has
been sent successfully; SM1159 is ON.
×
×
OFF
R OFF
*SM1160
When trigger 5 is triggered but the email cannot
be sent due to email content error; SM1160 is
ON.
×
×
OFF
R OFF
*SM1161
When trigger 5 is triggered and the email is
being sent; SM1161 is ON.
×
×
OFF
R OFF
*SM1162
When trigger 5 is triggered and there is an
SMTP server response timeout, SM1162 is ON.
×
×
OFF
R OFF
*SM1163
When trigger 5 is triggered and there is an
SMTP server response error, SM1163 is ON.
×
×
OFF
R OFF
*SM1164
When trigger 5 is triggered and the size of the
attachment exceeds the limit, SM1164 is ON.
×
×
OFF
R OFF
*SM1165
When trigger 5 is triggered and the attachment
is not found, SM1165 is ON.
×
×
OFF
R OFF
*SM1166
It is the switch of trigger 6 in the email.
×
×
OFF
R
OFF
*SM1167
Trigger 6 in the email
×
×
OFF
R
OFF
*SM1168
When trigger 6 is triggered but the email cannot
be sent due to the Ethernet connection failure;
SM1168 is ON.
×
×
OFF
R OFF
*SM1169
When trigger 6 is triggered and the email has
been sent successfully; SM1169 is ON.
×
×
OFF
R OFF
*SM1170
When trigger 6 is triggered but the email cannot
be sent due to email content error; SM1170 is
ON.
×
×
OFF
R OFF
*SM1171
When trigger 6 is triggered and the email is
being sent; SM1171 is ON.
×
×
OFF
R OFF
*SM1172
When trigger 6 is triggered and there is an
SMTP server response timeout, SM1172 is ON.
×
×
OFF
R OFF
*SM1173
When trigger 6 is triggered and there is an
SMTP server response error, SM1173 is ON.
×
×
OFF
R OFF
*SM1174
When trigger 6 is triggered and the size of the
attachment exceeds the limit, SM1174 is ON.
×
×
OFF
R OFF
*SM1175
When trigger 6 is triggered and the attachment
is not found, SM1175 is ON.
×
×
OFF
R OFF
*SM1176
It is the switch of trigger 7 in the email.
×
×
OFF
R
OFF
*SM1177
Trigger 7 in the email
×
×
OFF
R
OFF
*SM1178
When trigger 7 is triggered but the email cannot
be sent due to the Ethernet connection failure;
SM1178 is ON.
×
×
OFF
R OFF
*SM1179
When trigger 7 is triggered and the email has
been sent successfully; SM1179 is ON.
×
×
OFF
R OFF
*SM1180
When trigger 7 is triggered but the email cannot
be sent due to email content error; SM1180 is
ON.
×
×
OFF
R OFF

Table of Contents