Chapter 2 Devices
2-41
Limited
to
Special auxiliary
relay
Refresh time
AH5×1
1. The flag is refreshed after the Modbus TCP data exchange table
is downloaded.
2. The flag is refreshed after the system restoration is executed.
AH5×0
SM700-SM827
1. The flag is refreshed after the data exchange parameters are
downloaded.
2. The flag is refreshed every scan cycle.
AH5×1
Users set the flag to ON or OFF.
SM828-SM955
1. The flag is refreshed after the data exchange parameters are
downloaded.
2. The flag is refreshed every scan cycle.
SM1000~1003
Users set the flag to ON or OFF.
SM1089
The flag is refreshed every scan cycle.
SM1090
SM1090 is ON when the TCP connection is busy.
SM1091
SM1091 is ON when the UDP connection is busy.
SM1100
The flag is refreshed when API 2200/API 2201/API 2202/API
2203/API 2204/API 2205 is executed or the network cable is
reconnected.
SM1106
SM1106 is ON when the PHY initialization fails.
SM1107
SM1107 is ON when the IP address, the netmask address, and the
gateway address are set incorrectly.
SM1108
SM1108 is ON when there is a filter setting error.
SM1109
SM1109 is ON when the function of the socket is enabled and the
same port is used.
SM1112
SM1112 is ON when there is a setting error.
SM1113
SM1113 is ON when there is a server error.
SM1116
SM1116 is ON when the trigger of the PLC parameter is enabled.
SM1117
SM1117 is ON when the trigger of the PLC parameter is triggered.
SM1118
SM1118 is ON when the trigger is enabled and no mail has been
sent.
SM1119
SM1119 is ON when the trigger is enabled and the last mail has
been sent successfully.
SM1120
SM1120 is ON when the trigger is enabled and the last mail has
been sent in error.
SM1121
SM1121 is ON when the trigger is enabled and the mail has been
sent.
SM1122
SM1122 is ON when the trigger is enabled and there is an SMTP
server response timeout.
SM1123
SM1123 is ON when the trigger is enabled and there is an SMTP
server response error.
SM1124
SM1124 is ON when the trigger is enabled and the size of the
attachment exceeds the limit.
SM1125
SM1125 is ON when the trigger is enabled and the attachment is
not found.
SM1126
SM1126 is ON when the trigger of the PLC parameter is enabled.
SM1127
SM1127 is ON when the trigger of the PLC parameter is triggered.
SM1128
SM1128 is ON when the trigger is enabled and no mail has been
sent.
SM1129
SM1129 is ON when the trigger is enabled and the last mail has
been sent successfully.
SM1130
SM1130 is ON when the trigger is enabled and the last mail has
been sent in error.
SM1131
SM1131 is ON when the trigger is enabled and the mail has been
sent.