Appendix - User info codes _02/2017- 34 -
Type of
code
Code
no.
Description Resolution procedure
Error 236 ToolsNet FIFO full 1- The ToolsNet result FIFO is full, the CVINet connection has been lost
2- Check the CVI3 Ethernet cable
3- Check CVI3 Ethernet conguration
4- Check if ToolsNet is running correctly
Error 240 XML not authorized 1- The selected XML protocol is not authorized (check the ePOD
characteristics)
Error 243 PFCS not authorized 1- The selected PFCS protocol is not authorized (check the ePOD
characteristics)
Error 247 XML version conict 1- Conict detected in Audi / VW XML protocol version.
2- Check the coherence of the version between the controller and master
PC/PLC
Error 248 SAS order failed 1- Fieldbus SAS order has failed.
2- Check the value of RRGI, SIO, etc.
Error 249 XML PRG 0 1- The PRG value 0 has been set by Fieldbus.
Error 255 Drive choke too hot 1- Power electronics too warm.
2- Let the controller cool down.
Error 256 Motor too hot 1- Tool is locked because its maximum motor temperature has been
reached.
2- Tool will remain locked until the motor temperature comes back to its
normal value.
Error 260 IPM not authorized 1- The selected IPM protocol is not authorized (check the ePOD
connection)
Error 265 Socket(s) usable with more
than one TU
Recongure sockets combination to resolve conicts
Error 268 CVI NET incompatible CVI Net and CVI3 are incompatible. Please update CVI Net software
Error 502 CVILogix user info Message generated by CVILOGIX program
Error 890 Device Software Error Device Software Error
Error 915 Inconsistent version 1- The SW version of all CVI3 controllers must be identical
2- Update rmware
Error 916 Workgroup not authorized 1- You need to connect an epod3 on the Workgroup Primary controller
Error 918 Emergency stop ! 1- The emergency stop has been activated
2- Check the M8 connector
Error 919 Additional transducer error 1- The additional transducer's maximum torque is lesser than the
embedded transducer's maximum torque
2- The Pset uses an additional transducer though non is installed on tool