Frequently Asked Questions DECT
183
18.3 DECT
Note: In the following explanations it is assumed that a U
pn
interface card has been installed (in an OpenCom 130 or an
OpenCom 150).
The LED of the RFP 22/24 base station is flashing, but none of the DECT de-
vices is functioning.
Make sure the terminal setting for the corresponding U
pn
port is set to RFP 22/24
(Configurator, PBX Configuration: Ports: U
pn
menu).
If multiple RFP 22/24 base stations are installed, the blinking LED indicates that
synchronisation is not finished.
The LED of the RFP 22/24 is continuously lit up, but one of the cordless DECT
devices is indicating “No connection”.
You have not registered this DECT device. Configure a port in the Configurator
and start the enrolment procedure (PBX Configuration: Devices: DECT Phones
menu).
Is it possible to increase the time for the enrolment procedure?
You must manually enter the IPEI of the DECT device in the Configurator. The
enrolment time is then increased to one hour (PBX Configuration: Devices: DECT
Phones menu).
Another manufacturer’s DECT device is not functioning.
Check whether the DECT device supports the DECT GAP standard. In the Configu-
rator, also make sure GAP is set for this DECT device (PBX Configuration:
Devices: DECT Phones menu).
The startup procedure of the RFP 22/24 take a long time? What is the reason?
This behaviour may indicate a problem with the reference clock. Refer also to What
are some of the causes for problems when sending and/or receiving faxes? starting on
page 182.