0x17 cmdData
Length ChecksumStart Delimiter Frame Data
Identifier-specific DataAPI Identifier
MSB LSB0x7E 1 ByteAPI-specific Structure
Frame ID (Byte 5)
Identifies the UART data frame for the host to
correlate with a subsequent ACK (acknowledgement).
If set to ā0ā, no AT Command Response will be given.
Command Name (bytes
17-18)
Name of the
command
Set to match the 64-bit address
of the destination, MSB first,
LSB last. Broadcast =
0x000000000000FFFF. This field is ignored if the 16-bit
network address field equals anything other than
0xFFFE.
64-bit Destination Address
(bytes 6-13)
0x02 - Apply changes on remote. (If
not set, AC command must be sent
before changes will take effect.)
All other bits must be set to 0.
Command Options (byte 16)
If present, indicates the requested
parameter value to set the given
register. If no characters present,
the register is queried.
Command Data (byte 19-n)
16-bit Destination Network Address
(bytes 14-15)
Set to match the 16-bit network
address of the destination, MSB
first, LSB last. Set to 0xFFFE if 64-bit
addressing is being used.