DINO 240RXT
38
17.2 SERVICE AND INSPECTION INSTRUCTIONS
1. The first service after 20 hours of operation
- change the pressure and return filter elements
2. Daily service
- check the oil level in the hydraulics and the engine, top up if necessary
- check the hydraulic connections
- check the unit visually
- check the operation of the emergency descent and emergency stop functions
- check the operation of the safety devices
3. Weekly service
- check the tyre pressure (300 kPa)
- lubricate the joint pins (refer to the lubrication plan)
- check the sliding surfaces of the telescope and apply silicon if necessary
- check the clearance between the slide pads and surfaces and adjust the pads if necessary
- put a load of about 215 kg onto the platform and drive the boom to level position
Continue by extending the telescope until the red signal light lights up and the movement stops.
Measure the stroke in accordance with the instructions and compare it with the setting of the
outreach limit RK4. If the stroke exceeds the allowed value, contact the service person (see point
"Testing the outreach limit switch").
4. Service measures every six months
- change the hydraulic oil and both filters
- check the condition of the brakes
- grease the gear ring of the turning device bearing
5. Periodic service every 12 months ín accordance with the instructions for regular servicing
below in this manual
IF THE LIFT IS OPERATED UNDER DEMANDING CONDITIONS (IN EXCEPTIONALLY
HUMID OR DUSTY ENVIRONMENT, CORROSIVE CLIMATE, ETC.), THE INTERVALS
BETWEEN THE OIL CHANGES AND THE OTHER INSPECTIONS SHALL BE
SHORTENED TO MEET THE PREVAILING CONDITIONS IN ORDER TO MAINTAIN THE
OPERATIONAL SAFETY AND RELIABILITY OF THE LIFT.
THE PERFORMANCE OF THE PERIODIC SERVICING AND THE INSPECTIONS IS
ABSOLUTELY MANDATORY, BECAUSE THEIR NEGLIGENCE MAY IMPAIR THE
OPERATIONAL SAFETY OF THE LIFT.
THE GUARANTEE WILL NOT REMAIN VALID, IF THE SERVICING AND THE PERIODIC
INSPECTIONS ARE NOT PERFORMED.