DINO 240RXT
42
17.5 LOAD HOLDING AND LOAD REGULATION VALVES
Check of operation
1. To check the tightness of the outrigger cylinder load holding valves measure the height position of
the chassis from the floor separately at each outrigger. After a few minutes, measure the height
again.
2. To check the tightness of the load regulation valves on the boom cylinder and the cylinders of the
articulated arms drive the boom to a position in which its movement can be reliably measured.
Observe the possible movement of the boom in a few minute's time.
3. To check the tightness of the load regulation valve on the telescope cylinder extend the telescope
and stop the movement at any position, measure the stroke and observe in a few minutes time that
the stroke does not change. (Note! Drive the boom to an almost vertical position).
4. To check the tightness of the load regulation valve on the platform levelling system, put a load of
100 - 200 kg on the platform and measure the distance from the rear edge of the platform to the
floor. Observe for a few minutes that its height position does not change.
Service instructions
1. Disconnect and clean the valve
2. Check the O-rings and replace, if necessary
3. Put the valves carefully in place
4. Replace the valve, if necessary
5. Do not change the settings of the valves
Support the platform, boom system, articulated arm and outriggers in a position, where the load does not
rest on the structure under repair. Make sure to relieve the residual pressure from the cylinders.