DINO 240RXT
75
F11: Module XS-A0 10A (PK).
F12: Module XS-A0 10A (PK).
XP-A0 Power supply unit.
Bus module used for controlling the propo valves and relays and as a connection terminal for the
sensors.
XS-A0: Signal unit:
Bus module used for controlling the relays and as a connection terminal for the sensors.
20.2 CONTROL CENTRE 2 (OK2)
S1: Locking EMERGENCY STOP button.
Stops all other functions except the emergency descent and the sound signal, which remain
operational.
S13: Non-locking start button for emergency descent.
S16: Non-locking control switch for "swing right - left" on the chassis control panel.
S17: Non-locking control switch for "boom up - down" on the chassis control panel.
S18: Non-locking control switch for "telescope in - out" on the chassis control panel.
S19: Non-locking control switch for "articulated arms up - down" on the chassis control panel.
S20: Non-locking switch for levelling of the platform.
S30: Retracting the telescope After the SR3 has tripped, the telescope can be retracted by depressing the
button.
Q2: Switch lock:
Operation is only possible in the same operating position where the lift was started.
Position 0 = all electricity switched off
Position 1 = switches on the voltage to the control circuit of the main relay, the normal
operating position.
Position 2 = switches on the engine glowing.
Position 3 = start
H3: Signal light. The alarm display, the reason can be checked on the MDM display on the platform
control panel.
H6: Signal light. The signal light for engine glowing, the light is illuminated as the key switch is turned
to position Glowing.
The light only indicates that the key is in the glowing position, not e.g. how for long the glowing
current has been on.