20.6 OTHER MARKINGS
ALT: Alternator on the combustion engine.
B1: Battery 12VDC 68Ah.
E1: Thermo-relay for the engine M1.
GP: Glow plugs.
Switches off the fuel supply from the feeder pump as the solenoid is not energized.
LS: Inclination sensor.
M1: Electric motor 230VAC 16A. (Lisävaruste)
M2: Emergency descent unit 12VDC. Max. permissible operating time 10 min.
M3: Linear motor for the speed adjustment of the combustion engine.
M4: Turning motor of the platform.
MS: The main switch disconnects the minus terminal of the battery (Note! does not switch off the
engine during the operation).
NL: Unit for automatic levelling, brings the chassis to a horizontal position
P: Linear motor for the speed adjustment of the combustion engine.
PR: Socket outlet on the platform 230V / 50Hz / 10A
RPM: Engine rev sensor
SL: Starter solenoid of the combustion engine.
SR1: Solenoid for the emergency descent unit.
SS: Stop solenoid of the combustion engine.
S33: Pressure switch, monitors switching on of the second pump in the double pump unit powered by
the electric motor.
T: Temperature sensor of the combustion engine.
TR1: Angle sensor on the rear axle.
TR2: Angle sensor on the front axle.
TR3: Fuel sensor.
VVK: Fault current switch 25A 30 ms.
ÄM1: Sound signal.