FAULT REMEDY
15. Driving device does not operate
The brakes drag. Check the opening pressure of the brakes and
adjust to 2,5 MPa, if necessary.
Naturally the possible reasons for malfunctions are many, but the following are the most common:
- the battery is flat or the voltage is low
- contaminants in the hydraulic system
- loose electric connection or a contact failure caused by moisture