IP2348EN
Convenience battery 24V, DAS902BAT2 (00÷01)
When this parameter is set to On (01), with a 24V (UPS) battery
the operator will continue its normal operation in case of mains
power failure (flat batteries: last operation= opening /closing, see
parameter 36). Monitoring will be made if parameter 10 is set to
Convenience Monitoring (01).
Not approved in escape routes!
00 = Off.
01= On.
*NOTE: on DAS200TRG this display is not visible and is set to 00.
*NOTE: on DAS200TRF set to 00.
Emergency Unit Test Interval (04÷23hours)
The time set in this parameter controls the maximum time until
the next automatic test of the emergency unit is performed.
Battery Type (00÷02)
What type of battery that is mounted in the operator is identified
during the Learn.
00= No battery.
01= 12V (set parameter 43= 05).
02= 24V.
AUTOMATIC
Opening Delay For Lock (00÷99s x 0,1)
The time the opening is delayed (0.0-9.9sec) after an opening
impulse is given in operation mode selections OFF and EXIT.
If the DAS901BAT1 battery is used set parameter 43= 05.
Exit Lock (00÷01)
This parameter controls the electromechanical lock in the
operation mode selector setting EXIT.
00= Off. The electromechanical lock is not locked in EXIT.
01= On. The electromechanical lock is locked in EXIT, except
bistable lock.
NOTE: on DAS200TRF set to 00.
NOTE: If the Configuration Tool CT is used, disable the “learn
access”:
Learn AccessMMI Read accessMMI Write access
(DAS200TRG)
Stop Function (00÷01)
When this parameter is set to On (01) the Stop impulse is ena-
bled, otherwise it is disabled.
00= Off.
01= On.
Stop Configuration (00÷01)
00 = N.O.
01 = N.C.
Opening Max Force (02÷23N x 10)
The force applied from the operator to the door leaf during opening.
If the reopening maneuver occurs too abruptly, set parameter 49
with a value lower than the factory value (10), example 04 - 05.
Close Kick Force (00÷23N x 10)
The force applied from the operator to the door leaf during the
close kick.
Closing Max Force (02÷23N x 10)
The force applied from the operator to the door leaf during
closing.