43
EN
IP2348EN
Push&Close (00÷01)
When this parameter is set to On (01) the motor will in operation
mode selections OFF or EXIT try to close the door with the force
selected by parameter 50 “Closing Max Force”, if someone tries
to open it manually.
Push & Close is also known as “poor man’s lock”.
00= Off.
01= On.
Push & Close Timeout(00÷99s x 10)
Adjustable time for how long time the door will continue to “fight
back” when someone is trying to force it open.
00 = infinite time.
Operator Type (00÷04)
00= Slider.
01= DO NOT USE.
02= DO NOT USE
03= DO NOT USE
04= Mechanical Emergency Unit Slider (Sets for DAS200TRF).
NOTE: on DAS00T/DAS200TRG this display is not visible and
is set to 00.
Service needed Operating Hours (00÷60hours x 1.000)
Set time before yellow LED in operation mode selector will
start flashing.
To clear the service needed indication you have to push
on the MMI at the same time for 5 seconds when the display
shows on. After 5s the display will show “SE” during another
5s., release the UP and DOWN buttons. While the display
shows “SE” pres
and the Counters Operating hours
will be set to zero.
Service Needed Opening Cycles (00÷50 x 100.000)
Set time before yellow LED in operation mode selector will
start flashing.
To clear the service needed indication you have to push
on the MMI at the same time for 5 seconds when the display
shows on. After 5s the display will show “SE” during another
5s., release the UP and DOWN buttons. While the display
shows “SE” pres
and the Counters Operating hours
will be set to zero.
Low Speed Distance, Opening (00÷99cm)
“Creep speed” distance during opening.
Low Speed Distance, Closing (00÷99cm)
“Creep speed” distance during closing.
Status indication (00÷01)
The operator shows the status indication on the LED display
of the control panel. See paragraph 9.2 for more information.
00= Off.
01= On.
Default programming (00÷01)
Default programming sets the parameters to the factory default
values.
00= Off (It is not possible to perform a default programming
from the MMI).
01= On (It is possible to perform a default programming from
the MMI).