Side Presence Activation Distance (00÷99dm)
This is an inhibit signal for side presence. The door will act
according to the value entered in parameter 2A. The value has
to be according to local legislation. In an escape route the door
has to open to 80% of the certified distance (see parameter 11)
within 3 sec. after an inner impulse.
00= If value 00 is selected side presence impulse is valid from
fully closed to fully open position.
01-99= The distance is counted from open position.
During opening, the side presence impulse is inhibited until the
door reaches the entered value in the parameter.
Sensor Type (00÷01)
Select type of monitoring for the combined sensors. Choose
between 1-wire (00) or 2-wire (01) monitoring.
00= 1-wire monitoring. 1-wire monitoring is used when com-
bined sensors have only one monitoring input for both
presence and impulse field.
01= 2-wire monitoring. 2-wire monitoring is used when a
sensor has separate monitoring inputs for both presence
and impulse field.
Active Brake on Stop (00÷01)
00= Off. The door will freewheel until it stops.
01= On. The operator will brake the doors actively during 1s on
a Stop impulse.
Push & Go in EXIT and OFF Mode Selection (00÷01)
00= Off.
01= On.
Hold Force in EXIT and OFF Mode Selection (00÷01)
00= Off.
01= On.
With an electromechanical lock this hold force can be unnecessary.
Toggle Operation Mode Seector after Stop (00÷01)
In operation mode selection OFF the mode must be changed
before normal operation after a Stop impulse.
00= Off.
01= On.
Emergency Action (00÷01)
Fire closing/opening (ref. terminal 18-19 DAS902MP) or emer-
gency closing/opening by battery:
00=
Closing (The door will close on fire impulse or power failure
/ low battery).
01=
Opening (The door will open on fire impulse or power failure
/ low battery).
NOTE: on this DAS200TRG this display is not visible and is set to 01.
Emergency Action in OFF Mode (00÷01)
Decides if “Emergency Action” (ref. parameter 36) shall be
performed also in modes election OFF (= opens also in the
middle of the night).
00= Off.
01= On.
NOTE:
on this DAS200TRG this display is not visible and is set to 00.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DITEC DAS200TRF and is the answer not in the manual?

DITEC DAS200TRF Specifications

General IconGeneral
BrandDITEC
ModelDAS200TRF
CategoryDoor Opening System
LanguageEnglish

Related product manuals