48
EN
IP2348EN
i
Parameters from C0 to C9= FUTURE USE.
Choose group of the operation mode selector (00÷10)
This controls which MCU that looks at which OMS. It is possible
to group different OMS to different MCU. MCU and OMS with
same group number listens to each other. If a OMS is set to 0
this OMS controls all operators that is connected in that loop.
NOTE: function not available, do not modify factory setting.
FUTURE USE.
Choose display mode of the operation mode selector (00÷01)
In Show local mode the OMS shows the last setting made on
the OMS.
In Show system mode the OMS shows the setting that the ope-
rator is put to. It is shown with one flach every 5s.
When the OMS is flashing every 5s it is not possible to change
the mode on the OMS.
00= Show system mode.
01= Show local mode.
AUTOMATIC
(COM501ES/ER-
COM502ES/ER)
(COM500ES/ER)
Choose terminal mode of the operation mode selector (00÷02)
00=The buttons on OMS are disabled.
01= The OMS adapts to system mode.
02= The OMS keeps its selected mode.
AUTOMATIC
(COM501ES/ER-
COM502ES/ER)
(COM500ES/ER)
Mode selector, self service indication 00÷01)
COM500ES/ER. Orange flashing service LED.
COM501ES/ER, COM502ES/ER. Magenta flashing service LED.
Self service indication on operation mode selector.
00= Off. No self service indication.
01=
On. Indicate self service. Indicating a status or condition that can
be cleared by the owner e.g. a break-out door is standing open.
Mode selector, key impulse (00÷02)
If the selector is set on CLOSED DOOR, key impulse to the
operator can be made in the following ways by pushing the
symbol below.
COM500ES/ER,
COM501ES/ER, COM502ES/ER
00= Disabled. Disables the possibility to give key impulse.
01= Login Required. Login required on the OMS to enable the
possibility to give key impulse.
The login is configured through parameter 99 and B1.
02= Enabled. Enables the possibility to always give key impulse.
Bluetooth Power Mode (00÷02)
COM501ES/ER, COM502ES/ER
00= Always disabled. The Bluetooth Power Mode is fully disabled
until other mode is set.
01= Disabled in OFF mode. The Bluetooth Power Mode is disa-
bled in OFF mode.
02= Always enabled. The Bluetooth Power Mode is fully enabled
until other mode is set.