47
EN
IP2348EN
Operation mode selector key lock (00÷03)
COM501ES/ER COM502ES/ER
There are four different levels of access code choices for the
operation mode selector.
COM500ES/ER
There are three different levels of access code choices for the
operation mode selector.
00= No access code (Not allowed in escape route, according to
EN16005 and DIN18650).
01= Hold for two sec (Not allowed in escape route, according to
EN16005 and DIN18650).
COM500ES, access is obtained by holding
or for 2
seconds.
COM501ES, COM502ES, access is obtained by holding any mode
selection button for 2 seconds.
02= Passcode.
COM500ES, passcode can be selected where the access is
obtained by briefly pushing in turn
.
The entire passcode must be entered within 3 seconds.
(Not allowed in escape route, according to EN16005 and
DIN18650).
COM501ES, COM502ES, passcode can be selected where the
access is obtained by briefly pushing the buttons in correct order.
The entire passcode must be entered within 10 seconds.
The passcode can be changed through the DAS900CT.
Default passcode is
.
03= Key
COM501ER /COM502ER
To enable the use of the selector, rotate the key clockwise
towards the symbol
.
COM500ER
Mode selector is not affected by this parameter.
See parameter 99.
Operator mode selector service indication (00÷01)
Yellow flashing service LED. Service indication on operation
mode selector. No service indication (00). Indicate service (01).
00= Off
01= On
Choose priority of the operation mode selector (25÷99)
The lower the number the higher the priority.
NOTE: function not available, do not modify factory setting.
FUTURE USE.