ParaMon-Pro X instruction manual DOC.60391-01/21
37
G.Snug torque
Sets the measurement point of angle values used in judging OK/NG.
‘0’ refers to ‘Disabled’. Angle measurement begins as soon as the tool is operated.
If not ‘0’, angle measurement starts as soon as the torque reaches the snug torque value.
Setting snug torque to a value other than ‘0’.
In other words, alteration of the angle measurement point means the application of angle values in judging
OK/NG.
If the snug torque is not ‘0’, therefore, both minimum and maximum angle values should be set together.
H.Speed (RPM)
Able to set tool speed in person
Not permitted to modify if the Controller Auto Speed settings are ‘ON’.
Able to modify if the Controller Auto Speed settings are ‘OFF’.
I.Free Angle & speed
If the free angle value is ‘0 (disabled)’, the system is operated at ___ speed (RPM) until the seating point.
If the free angle value is not 0’, the system is operated at free speed until the free angle. Since the free angle,
it is run at ___ speed (RPM).
Mostly used to reduce fastening time.
In case of relatively long screws, fastening time can be reduced by setting free angle and speed to proper
levels and increasing operating speed in the beginning when torque is relatively weak.
Recommended to set the free angle to a level lower than the overall angle by at least 2 turns (720°).
J.Soft Start (ms)
Able to adjust acceleration until the target speed is reached.
Able to set the time taken to reach target speed after the start of tool operation, using ‘Controller
Acceleration (ms)’.
Here, ‘Acceleration (ms)’ refers to a value commonly applied to all presets.
Able to control acceleration by preset, using Soft start (ms) additionally.
In other words, total time taken to reach target speed can be obtained as follows: ‘Controller Acceleration
(ms)’ + ‘Soft start (ms)’.
The above target speed can be interpreted differently depending on situations.
Unless free angle & speed is set, target speed is ___ (RPM).
If free angle & speed is set, target speed becomes ‘free speed (RPM)’.