ParaMon-Pro X instruction manual DOC.60391-01/21
48
M. Driver model
Sets a driver model.
Do not randomly alter without discussion with the manufacturer.
Such unauthorized alteration may result in incorrect operation and system failure.
N. Controller parameter initialize
Enter ‘77’ to reset all settings to the default settings.
O. Torque holding time (ms)
After reaching target torque, the force is kept for a while.
Excessive time setting can cause heating.
This function is not available in BMT lines.
P. Auto speed
According to target torque settings, proper speed is automatically set.
Recommended to use in ON state.
If AUTO Speed is turned OFF, and ‘Preset Speed’ is set too high to reduce fastening time, the fast rotating
screws can stop abruptly, and over torque (torque ripple) can occur due to inertia.
Q. Judged fasten min. turns
It becomes the gauge to judge if a user executes the trigger intentionally.
The default setting is ‘3.0 turns’.
It is reasonable to conclude that a user intentionally executed the trigger after 3.0 turns (1,080°).
For more information, refer to ‘Fastening stop error’.

Table of Contents