10
System Fault Squawk
Yes = Causing a Zone tamper, zone fault or a Module tamper will cause all Burglary outputs to
squawk every 5 seconds (included are fire/burg, invert fire/burg, burg. and invert burg) for
the partition(s). The “Squawks” will be silenced when the alarm is silenced or a key is
pressed on that partition. By default this option is set to No.
No = Zone Tampers, Faults and Module Tampers will not squawk the burglary outputs.
Code Display Inhibited
Yes = When programming Access codes ([*][5] Access code Programming) the code numbers
will be X’d out ([XXXX] or [XXXXX] if using 6 digit access codes). By default this option is
set to No.
No = The digits of the access code will be displayed •as entered on the keypad being used for
programming.
Global Alarm Annunciation
Yes = This system toggle will allow the Global keypads to sound the buzzer (5 seconds on and 5
seconds off) and display the message “Partition X In Alarm” (where Partition X is the
programmed label of the partition) when any other partition is in alarm. The buzzer will be
silenced and the message cleared from the keypad display when the alarm has been
silenced or any key is pressed on the keypad. By default this option is set to No.
No = No notification of the alarm will be given on the Global Keypad.
Note: It is recommended that global alarm annunciation is enabled on multi partition systems.
Global Keypad Trouble
Yes = Troubles present on the system can be viewed from global keypads. If a trouble is present
on the system, the user will be prompt with the option to view system troubles.
No = Troubles can not be viewed from global keypads. The keypad must be loaned to a partition
before troubles can be viewed.
Global Keypad Partition Status Enunciator
Yes = Enables the Partition Status Enunciator on global keypads. Global keypads will display the
status of all active partitions on the system.
No = Global keypads will not display the Partition Status Enunciator.
Note: This option overrides the clock display option.
Global Keypad Enunciates All Entry Delays
Yes = The entry delay for any Partition will be enunciated on Global Keypads.
No = All Partitions must be armed before entry delay will be enunciated on Global Keypads.
GLOB ALM ANNUN
N
SYS.FLT.SQUAWK
N
CD DISP INHIBIT
N
SYSTEM AREA
SYSTEM OPTIONS
SYS TOGGLE OPT
GLB KP ALL ENT
N
GLB KYPD TRB
Y
GLB KYPD STAT
N