45
SYSTEM AREA
EVENT SCHEDULING
EVENT
SCHEDULING
EVENT SCHEDULING
(10)
OPEN/CLOSE SUPPR
(0)
Event scheduling allows for a variety of timed events to occur on specific dates and times.
Openings and Closings can be suppressed during high traffic times, outputs may be programmed
to follow Date Schedules and partitions may be Auto Armed and Auto Disarmed by specific times
programmed in the Date Schedule.
This group of schedules can be programmed to suppress openings or closing (each schedule is
capable of suppressing either opening or closings only) for any partition on the system. There are
99 different Open/Close Suppression schedules that the panel is capable of following. Each
schedule is programmed to follow one of 99 Date Schedules. Date Schedules is where the time(s)
for the Open/Close Suppression schedule are programmed. If desired the schedule can be
programmed to follow a Holiday Schedule this will allow the Schedule to have exceptions. Each
Schedule may be programmed to function for one or more partitions at the same time.
Programming sections of Open/Close suppression are:
Openings Y/N - Selects to suppress openings or closings - Default N
Date Schedule # 01 - 99 - Selects the date schedule to follow - Default 01
Partition Mask - Selects the Partition(s) to be active on - Default All off
An example of an Open/Close Suppression Schedule:
Open/Close Suppression Schedule 05 is programmed with;
Openings - Y
Sch. # (Date Schedule Number) - 03
Partition 1 - Y Partition 5 - N
Partition 2 - Y Partition 6 - N
Partition 3 - N Partition 7 - N
Partition 4 - N Partition 8 - N
Date Schedule - 03 is programmed with;
Interval 1 Interval 2
Start Time 0730 Start Time 1630
End Time 0930 End Time 1830
Sunday N Sunday N
Monday Y Monday Y
Tuesday Y Tuesday Y
Wednesday Y Wednesday Y
Thursday Y Thursday Y
Friday Y Friday Y
Saturday N Saturday N
Holiday 1 N Holiday 1 N
Holiday 2 N Holiday 2 N
Holiday 3 N Holiday 3 N
Holiday 4 N Holiday 4 N
Autoarm N Autoarm N
Autodisarm N Autodisarm N
Intervals 3 - 4 are left unprogrammed.
In this example Open/Close Suppression schedule 05 will suppress openings for partitions
1 and 2, following Date Schedule 03 Monday to Friday 7:30 AM to 9:30 AM and 4:30 PM to
6:30 PM In this example Holiday Schedules and Autoarm/Disarm Schedules are not used.
Notes: In an opening suppression window if a partition is disarmed with alarms in
memory the opening (or Autodisarming) and opening after alarm will be transmitted.
In a opening/closing suppression window the openings and closings will be logged to
the event buffer, but no transmission will be made for the event.
Date Schedules are used by the panel to control the times that an event will occur. There are 99
Date schedule each containing 4 intervals. Date schedules are used by Open/Close Suppression
Schedules, Holiday Schedules, Autoarm/Autodisarm Schedule and the Date Schedule Output
(See PGM OUTPUT OPTIONS).
Interval - An Interval is used by the control panel to determine the time(s) and day(s) that a
schedule is to be active and if the schedule should follow a Holiday Schedule or Autoarm/
Autodisarm schedule.
DATE SCHEDULES