Zone Options
Enabling or disabling options by zone.
Bell Audible?
YES = An alarm causes the bell output to activate.
NO = Silent alarm.
Bell Pulsed?
YES = The bell output will pulse when the zone is in alarm.
NO = The bell output will be steady when the zone is in alarm.
Zone Bypass Enabled?
YES = The zone may be manually bypassed.
NO = The zone cannot be bypassed.
Door Chime Function?
YES = Every keypad on the partition will chime both when the zone is violated and when the
zone is then secured. The partition must be disarmed for the chime option to function.
NO = The zone will not chime the keypads.
Zone Can Force Arm?
YES = The partition may be armed with the zone violated. The zone will be temporarily
bypassed, and when the zone is secured it will be added back into the system.
NO = The partition cannot be armed if this zone is open.
Swinger Shut Down?
YES = After a zone causes a programmed number of alarms, the zone will shut down so that no
further transmissions are sent to the monitoring station. The bell can follow Swinger Shut
Down if programmed. (See “Shut Down 24 Hrs ”, “Swinger Limit” and “Bell Shut Down.)
NO = Swinger Shut Down disabled.
Transmission Delay?
YES = The reporting of zone alarm will be delayed for the programmed time. If the system is
disarmed within this time, no alarm signal will be communicated. (See “Zone TX
Delay”.)
NO = When an alarm occurs, the reporting code is transmitted immediately.
Partition Label
Programming a partition name label. This label is programmed in the same manner as LCD
messages or custom zone ID (see “Event Messages”).
Note: The maximum length of the partition name label is 14 characters.
ZONE OPTIONS
(2)
BELL AUDIBLE
Y
BELL PULSED
N
BYPASS ENABLED
Y
CHIME FUNCTION
Y
FORCE ARM
N
SWGR SHUT DOWN
Y
PARTITION AREA
ADD/EDIT PAR
ZONE ASSIGNMENT
ADD/EDIT ZONES
TX DELAY ?
N
PAR NAME LABEL
(4)