52
PARTITION AREA
ADD/EDIT PAR
ZONE ASSIGNMENT
ZONE TYPE
Zone Assignment
This section is for assigning type and options for each individual zone.
By default, the first 8 zones on the main panel are assigned to partition 1. If zone expanders have
been enrolled, the zones must be added to a partition for the PC4010 to be able to monitor them.
Upon entering this section, the zones which have not been assigned to the selected partition will
be displayed. Use [<][>] keys to scroll through the zones, and the [Q] key to select which zone to
add to the selected partition.
Global Zones: If zone(s) are added to more than one partition (global zones), the zone(s) will
follow the following rules:
• A global zone is not armed until all partitions which the zone belongs to are armed.
• A global delay zone will follow the longest delay of all partitions which it is assigned to. For
example, if Partition 1 has an entry delay of 30 seconds and Partition 2 has an entry delay of 45
seconds, the global delay zone will not be in alarm until Partition 2 finishes with its entry delay.
• If one or more partitions that a global interior home-away zone(s) belongs to is [Q] [9] armed
(At-home Armed), and the other partitions which the zone(s) belongs to are not, the zone will
not be active until the interior zones are activated ([Q] [1]).
• If a global zone is manually bypassed and any partition that the zone belongs to is disarmed,
the bypass will be removed from the zone.
This section is for editing zones which have already been assigned to a partition. Upon entering
this section, the zones which have been assigned to the selected partition will be displayed. Use
the [<] [>] keys to toggle through the zones, and the [Q] key to select the zone to edit.
Deleting zones from the partition. When selecting which zone to delete, the keypad will only
display zones which are assigned to the partition.
Each zone can have its own unique label to help identify it on the LCD keypad. Upon first
entering this section, the LCD will display the current zone label. See ‘Label Programming’ in
Event Messages.
Note: The maximum length of the zone label is 14 characters.
Zone Type
Select the zone type for the selected zone. Upon entering this section, the current programmed
zone type is displayed.
For example, zone 01 will display ‘Standard Delay’ the first time it is programmed. The default
setting is for Standard Delay. All other zones (02 through 64) are instant zones by default.
Note: Every time a new zone type is selected, the zone options for the selected zone will be set
to a default setting. The default setting will be different depending on the zone type selected.
Zone Options Zone Type Default Settings
Bell Audible Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y N N N N N N N
Bell Pulsed N N N N N N N N N Y Y Y N N N N N N Y N N N
Bypass Enabled Y Y Y Y Y Y Y Y Y N N N N N N Y Y Y N N N N
Chime Function Y Y Y N N N N N N N N N N N N N N N N N N N
Force Arm N Y N N N N N N N N N N N N N Y Y Y N N N N
Swgr Shut Down Y Y Y Y Y Y N N N N N N N N N N N N N N N N
Tx Delay ? N N N N N N N N N N N N N N N N N N N N N N
For example, if zone 009 is programmed for zone type “24 HR BUZZER”, the zone options “BELL
AUDIBLE” and “BYPASS ENABLED” will be enabled, and all other options will be disabled for
zone 009.
DELETE ZONE
(2)
ZONE LABEL
(0)
ZONE TYPE
(1)
EDIT ZONE
(1)
Standard Delay
Auxiliary Delay
Instant
Interior
Int Home Away
Delay Home Away
24 hr Bell
24 hr Bell/Buzz
24 hr Buzzer
Standard Fire
Delayed Fire
Auto Ver Fire
Momentary Arm
Maintained Arm
Latching 24 hr
Forced Answer
Links Supervisory
Links Answer
Sprinkler
Hold Up
Panic
Technical
ZONE ASSIGNMENT
(3)
ADD NEW ZONE